We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Neutralization Device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Neutralization Device Product List and Ranking from 7 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

Neutralization Device Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. タクミナ Osaka//Industrial Machinery
  2. エイチツー Aichi//Machine elements and parts
  3. シーズ Osaka//Industrial Machinery
  4. 4 レゾナック・ガスプロダクツ Kanagawa//Resin/Plastic
  5. 5 トーケミ Osaka//Industrial Machinery

Neutralization Device Product ranking

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. Boiler Drainage Dedicated pH Neutralization Device 'No Cooling Water Needed for High-Temperature Drainage at 80°C! BK' タクミナ
  2. Automatic pH Neutralization Device 'This One Device for Water Supply and Distribution pH Neutralization! NPK' タクミナ
  3. Alkaline wastewater neutralization device レゾナック・ガスプロダクツ
  4. pH Automatic Neutralization Device Comprehensive Catalog トーケミ
  5. 4 Seas [24-hour continuous unmanned operation possible!] Automatic pH neutralization device シーズ

Neutralization Device Product List

1~15 item / All 38 items

Displayed results

Boiler Drainage Dedicated pH Neutralization Device 'No Cooling Water Needed for High-Temperature Drainage at 80°C! BK'

Can neutralize high-temperature wastewater up to 80℃ without cooling water! Boiler wastewater dedicated pH neutralization device 'BK'

The pH neutralization device 'BK' from Takumina, a leading company in precision pumps, is designed specifically for boiler wastewater and can neutralize high-temperature wastewater up to 80°C without the need for cooling water, making it highly recommended for environmental measures regarding boiler wastewater. ■ Accepts raw water temperatures up to 80°C In conventional neutralization processes, cooling water was injected to reduce the raw water temperature below 40°C, but with the ability to handle high temperatures (below 80°C), cooling water is no longer necessary in most cases. Furthermore! The stainless steel neutralization tank has improved heat resistance and corrosion resistance compared to conventional models. The Takumina chemical injection unit <PTS series>, known for its durability, is standard equipment for chemical injection. We will help you select and introduce the most suitable products for your needs, so please feel free to contact us.

  • 0.jpg
  • A.png
  • 3.png
  • 4.png
  • 5.png
  • 2.png
  • Water treatment equipment
  • Boiler
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Alkaline wastewater neutralization device

For water purification plants and various factory wastewater! High reaction efficiency contributes to reduced running costs!

The "Alkaline Wastewater Neutralization Device" achieves high reaction efficiency by adopting a specialized mixer, which has a proven track record as a gas-liquid mixing device in a wide range of fields such as beverages and agriculture, at the core of the reaction unit. As a result, it reduces the amount of gas used, compacts the device, and improves both maintainability and reliability. Additionally, by using chemicals in conjunction with carbon dioxide, abnormal pH drops due to excessive injection do not occur. By automatically proportionally controlling the chemical supply according to the wastewater, stable and highly reliable treatment is possible. 【Features】 ■ High reaction efficiency with low chemical usage ■ Short processing time and compact device ■ No abnormal pH drops due to excessive injection ■ Automatic proportional control of chemical supply according to wastewater ■ Easy operation with the possibility of automatic operation ■ Easier maintenance due to the disassemblable mixer compared to conventional products *For more details, please refer to the PDF materials or feel free to contact us.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

pH Neutralization Device [Gas Injection Method] PHG Series

Safe and compact design! pH neutralization treatment device that does not generate secondary pollution.

The "PHG Series" is a pH neutralization treatment device designed to be safe and compact, preventing secondary pollution. It is suitable for alkaline wastewater from ready-mixed concrete plants, concrete product factories, as well as crushed stone factories and construction sites. 【Features】 ■ Neutralization method: Carbon dioxide neutralization method ■ Suitable for alkaline wastewater ■ Provides equipment tailored to treatment flow rate, pH value (and whether there are fluctuations), and temperature based on the characteristics of the raw water ■ An optional pH abnormality alarm (buzzer and patrol light) is also available *For more details, please refer to the PDF document or feel free to contact us.

  • pHg-flowsheet.jpg
  • Wastewater/wastewater treatment equipment
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

pH Automatic Neutralization Device Comprehensive Catalog

We offer three types according to your needs (continuous, batch, and carbon dioxide types)!

We offer a unit product by combining various water purification equipment, primarily focusing on our own products.

  • Water treatment equipment
  • Wastewater/wastewater treatment equipment
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Neutralization of Air Conditioning Drainage Water

Clear all setup space, safety regulations, and costs!

●Cleared all requirements for installation space, safety regulations, and costs! We received an inquiry for a neutralization system for air conditioning drain water from major glass manufacturer A. Processing capacity: 0.2m3/h, pH: 2.5~. At H2, we conducted thorough hearings with the user to ensure compliance with their safety regulations and installation space, holding multiple meetings. ●Custom-made production - The control panel was designed with usability in mind and to fit within the budget. - The neutralization tank is made of PE, also considering cost balance. - The chemical tank is designed larger to minimize the need for frequent chemical replenishment. - Space-saving design We manufactured it to meet all the user's requirements.

  • 図16.png
  • 図17.png
  • 67.png
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Neutralization Treatment of High-Temperature Wastewater

We introduce case studies of automatic pH neutralization systems that can handle both high-temperature acidic wastewater and alkaline wastewater!

We received an order for the pH neutralization treatment, including construction, due to the addition of a new line from a food factory. All tanks were selected as heat-resistant tanks (80°C) due to the high-temperature wastewater. The pH meter was also changed to a high-temperature specification, and our heat-resistant submersible pump model JCVH was incorporated into the raw water pump. The user's wastewater is discharged in batches, and depending on the situation, it can be either acidic or alkaline. Therefore, we implemented control on both sides to accommodate either condition for neutralization. A vertical mixer for dilution stirring was installed in the sulfuric acid tank. The shaft and impeller were processed with FRP lining for sulfuric acid resistance. We adopted our electromagnetic pump for both sulfuric acid and caustic soda injection pumps. [Case Study] ■ Delivery: Food factory in Saitama Prefecture ■ Application: Neutralization treatment of factory wastewater, including boiler discharge (high temperature) *For more details, please refer to the PDF document or feel free to contact us.

  • 77.jpg
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Neutralization Treatment of High-Temperature Alkaline Wastewater from Dishwashers

We introduce case studies of the delivery of automatic pH neutralization devices for both small-scale and special neutralization, focusing on cost and response!

We received an order for the installation of a large dishwasher, including pH neutralization treatment, from a major research institution. Since the wastewater discharged from the dishwasher is high-temperature, all tanks were selected to be heat-resistant (80°C). The pH meter was also changed to a high-temperature specification. The wastewater from the dishwasher fell by its own weight, so we raised the level of the dishwasher slightly to accommodate this (using a support frame). Additionally, due to the low liquid level that could flow into the neutralization tank, we designed a custom specification to allow for rapid neutralization, proposing a compact and cost-effective design, which was ultimately adopted. [Case Study] ■ Delivery: Research institution in Aichi Prefecture ■ Application: Neutralization treatment of high-temperature alkaline wastewater discharged from the dishwasher *For more details, please refer to the PDF document or feel free to contact us.

  • image_02.jpg
  • image_03.jpg
  • 79.jpg
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Neutralization Treatment of High-Temperature Boiler Drainage

Introducing a case study of neutralizing 80℃ boiler drain water in a space-saving manner.

A major plant engineering company consulted us about installing a high-temperature alkaline boiler wastewater neutralization system in a new building in Tokyo, seeking a space-saving solution. The space for the neutralization process was very limited, so we devised various strategies to optimize space usage. Additionally, due to the need for complex temperature management, we implemented a dedicated touch panel control for the site. This was evaluated as making site management significantly easier. [Case Study] ■ Delivery: A certain high-rise building in Tokyo ■ Application: Neutralization treatment of 80°C boiler wastewater *For more details, please refer to the PDF document or feel free to contact us.

  • image_07.jpg
  • image_08.jpg
  • 81.jpg
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Neutralization Treatment of Pickling Waste Liquid

A flexible neutralization treatment equipment manufacturer! A case of receiving an order for neutralization treatment equipment including all construction!

To a stainless steel processing company in Shiga Prefecture, we delivered an "automatic pH neutralization device" for neutralizing the waste liquid generated during acid pickling. What the company required was to "remove the existing neutralization device and install a new one." We proposed the removal work, new installation work, and the design of the neutralization device tailored to the available space, resulting in a site that satisfied the customer. [Case Study] ■ Delivery: Stainless steel processing company in Shiga Prefecture ■ Purpose: Neutralization of waste liquid generated during acid pickling ■ Model: Automatic pH neutralization device *For more details, please refer to the PDF document or feel free to contact us.

  • Machinery and equipment installation/dismantling/relocation

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Delivery Example] Asbestos Cleaning Water Vehicle Neutralization Device

Neutralization treatment of cleaning water containing asbestos! A case that addresses both alkaline and acidic sides.

We received an inquiry from a removal and demolition contractor in Hiroshima Prefecture regarding the pH neutralization treatment of asbestos-containing wash water. They requested that we be able to handle both acidic and alkaline wastewater, so we addressed this with additional design. It was noted that the sludge would settle in a sedimentation tank provided by the customer during the pre-treatment stage, so we configured the flow to only suck the supernatant using a float skimmer and an ADD-type air diaphragm pump. We also ensured that the integration with the neutralization treatment process could be completed with a single control panel, and we addressed the pressurization for further filtration of the neutralized raw water using the ADD type. [Case Study] ■ Delivery: Removal and demolition contractor in Hiroshima Prefecture ■ Application: Neutralization treatment of asbestos-containing wash water (truck-mounted specification) *For more details, please refer to the PDF document or feel free to contact us.

  • アスベスト1.png
  • アスベスト2.jpeg
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Neutralization device for dialysis wastewater

Neutralization equipment for dialysis wastewater, which has been supplied to almost all industries, including food and chemicals.

This product is a pH neutralization treatment device for dialysis wastewater, designed to suit the number of user floors. We will design the device to fit within the specified installation space, making it adaptable to any compact area. To tailor the design to the user’s needs, we will create a dedicated flow diagram after the inquiry. 【Features】 ■ "Semi-custom" concept ■ Designed to suit the number of user floors ■ Adaptable to any compact area ■ Dedicated flow diagram created after inquiry ■ Extensive delivery track record *For more details, please refer to the PDF materials or feel free to contact us.

  • image_842.png
  • image_843.png
  • image_844.png
  • image_845.png
  • image_846.png
  • image_847.png
  • image_848.png
  • image_849.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Update of Neutralization Equipment Due to Aging at a Ready-Mixed Concrete Plant

Customized installation layout for our customers! We will introduce a case study of the automatic pH neutralization system delivery.

We received a message from a major concrete factory in the Kanto region stating, "We are considering updating our existing neutralization equipment due to its aging." It seemed that price was a priority for them, but the proposal from the salesperson who conducted the site survey, along with the fact that our company could handle both the installation and removal work, was highly evaluated, leading to their decision to adopt our solution. They wanted to minimize the hassle of chemical replenishment, so we selected a 2m3 tank for the chemical storage. The installation location was also separate from the main neutralization equipment. Since the chemical replenishment would be done via a tanker, we prepared the tanker piping as well. Additionally, we arranged for the chemicals themselves. Furthermore, to ensure that pH fluctuations are automatically recorded, we added a recorder as an option, which was appreciated for its flexible construction and design. [Case Details] ■ Delivery: Kanto Ready-Mixed Concrete Factory ■ Application: pH neutralization treatment of concrete wastewater *For more details, please refer to the PDF document or feel free to contact us.

  • image_02.png
  • image_03.png
  • image_04.png
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Case Study】Neutralization of High-Temperature CIP Wash Water

Designing a flow tailored to our customers! We will introduce examples of delivered automatic pH neutralization systems.

We received a message from a major food factory in Kansai stating that they are "looking for a neutralization device for CIP wastewater discharged from a newly established factory." Due to the complexity of the control, we proposed using a sequencer (touch panel). They appreciated that we could handle the entire construction, leading to our adoption. If neutralization does not occur for any reason, they cannot stop the equipment line. Therefore, considering all possibilities, we designed a flow that returns to the raw water tank if the average value of the two electrodes installed in the discharge tank is NG. Additionally, during the construction phase, we held discussions from the foundation design stage and worked with the user on the buried pipes from the raw water tank (concrete pit). The person in charge evaluated us by saying, "It was great to have a sales representative with technical skills whom we could entrust everything to." [Case Study] ■ Delivery: Major food company in Kansai ■ Application: pH neutralization treatment of CIP cleaning wastewater *For more details, please refer to the PDF document or feel free to contact us.

  • image_05.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Delivery Example] New Construction Dialysis Drainage pH Neutralization Treatment System

Introducing a case study of the delivery of a compact automatic pH neutralization system!

We received an inquiry from an architectural design company regarding a neutralization system for a clinic that is planned to be newly constructed. Since this is a meeting at the architectural design stage, we discussed details such as the drainage route, the space for the neutralization system, and the positions of the inlet and drainage pipes. Additionally, discussions with the architectural design company included the installation location, plumbing, electrical aspects, and specifications of the neutralization system, which were also coordinated with the dialysis machine manufacturer (Nipro) to proceed in detail. With 90 beds, the required processing capacity was somewhat larger, but we were able to clear the space requirements, and we managed to compactly integrate everything, including receiving all drainage through the storage tank on the Nipro side with the neutralization system. [Case Summary] ■ Consultation Details - Considering a neutralization system for a clinic that is planned to be newly constructed. ■ Results - With 90 beds, the required processing capacity was somewhat larger, but we were able to clear the space requirements. - We were able to compactly integrate everything, including receiving all drainage through the storage tank on the Nipro side with the neutralization system. *For more details, please refer to the PDF document or feel free to contact us.

  • 2022-02-08_16h34_46.png
  • 2022-02-08_16h34_52.png
  • 2022-02-08_16h34_59.png
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] pH Treatment of Experimental Wastewater for Universities

Designed to complete neutralization in one tank! Design companies struggling with wastewater treatment, please consult us!

We would like to introduce a case study of the automatic pH neutralization system we delivered. We received an inquiry from a design office that wanted to neutralize experimental wastewater generated due to new construction. The client was a university in the Chubu region, and they requested treatment for wastewater resulting from experiments related to cement and concrete. Since they were looking for a compact and simple device, we designed it to complete the neutralization in a single tank. Because we were able to hold meetings before the new construction work began, the foundation (concrete) was prepared perfectly, and the handover of operations from the design company went smoothly. Our company has a system in place that allows for appropriate proposals and the realization of our customers' "wants" through collaboration between sales and design. Please feel free to contact us when you need our services. *For more details, please refer to the PDF materials or feel free to contact us.

  • image_02.png
  • image_03.png
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration